Home :: Free Items :: FREE Other file types :: EKW FX10 Installation Manual 50 HZ HYDRONIC HEAT PUMPS

EKW FX10 Installation Manual 50 HZ HYDRONIC HEAT PUMPS

EKW FX10 Installation Manual 50 HZ HYDRONIC HEAT PUMPS

Table of Contents

General Installation Information ............................................4

Accessories & Other Options ................................................5

Potable Water Systems .....................................................6-7

Open Loop Systems ..............................................................8

Earth Coupled Systems .........................................................9

Electrical .........................................................................10-11

Small EKW Setup/Operation ...............................................12

1. Application Overview .......................................................14

2. Inputs and Outputs Configuration ....................................14

3. Sequence of Operation ...................................................15

3.1. Power Fail Restart .................................................15

3.2. Random Start Delay ..............................................15

3.3. Compressor Fixed On Delay Time ........................15

3.4. Compressor Minimum On Delay ...........................15

3.5. Compressor Short Cycle Delay Time ....................15

3.6. Heating Cycle ..................................................15-16

3.7. Cooling Cycle ........................................................16

3.8. Emergency Shutdown ...........................................17

3.9. Lockout Mode ........................................................17

3.10. Entering Load Water Temperature (AI-1) ............18

3.11. Leaving Load Water Temperature (AI-2) .............18

3.12. Entering Source Water Temp (AI-3) ....................18

3.13. Source Low Water Coil Temperature Limit (AI-4) ..18

3.14. Load Low Water Coil Temperature Limit (AI-5) ...18

3.15. Leaving Source Water Temp (AI-6) .....................18

3.16. Compressor Proving (BI-1) .................................18

3.17. Emergency Shutdown (BI-2) ...............................18

3.18. Low Pressure Switch (BI-3) ................................18

3.19. Source Side Low Water Coil Temperature Limit Select (BI-4) ...................................19

3.20. Load Side Low Water Coil Temperature Limit Selection (BI-5) ....................................................19

3.22. Y1/System Enable Command (BI-7) ...................19

3.23. Source Flow Proving Switch (BI-8) .....................19

3.24. Aqua-stat O/Heating-Cooling Select Command (BI-9) ................................................19

3.27. Load Flow Proving Switch (BI-12) .......................20

4. Outputs ............................................................................20

4.1. Reversing Valve (BO-1) .........................................20

4.2. Compressor (BO-2) ...............................................20

4.3. Reversing Valve (BO-3) .........................................20

4.4. Secondary Unit Enable (BO-4) ..............................20

4.5. Secondary Unit S-Plan Comfort Select Enable (BO-5) ..............................................................20

4.6. Alarm Output (BO-6) .............................................20

4.7. Accessory Output 1/Source Pump Control (BO-7) ..............................................................21

4.8. Accessory Output 2/Load Pump Control (BO-8) ..............................................................21

Unit Startup .........................................................................22

ARI/ISO/BS EN Ratings ......................................................23

Capacity Data ................................................................24-39

Source Flow Rates (L/s) ......................................................40

Pressure Drop (kPa) ............................................................40

Troubleshooting ...................................................................41

Preventive Maintenance ......................................................42

Details
SKU SKU11052
Weight 0.20 Kgs
 
Our price: FREE to download
 
Quantity 1 (this product is downloadable)
: *
: *
: *
Type the characters you see in the picture:


*
POWER MAINS & HARMONIC FILTERS
FIXED EQUIPMENT - COMPACTOR
INSTALLATION INSPECTION GUIDE FOR ELECTRICAL
POWER MAINS & HARMONIC FILTERS FIXED EQUIPMENT - COMPACTOR INSTALLATION INSPECTION GUIDE FOR ELECTRICAL
£6.00
£6.00
 
INDICATOR BOARD
LEV SPRAY BOOTH
FINAL CIRCUITS - CONTACTORS
INDICATOR BOARD LEV SPRAY BOOTH FINAL CIRCUITS - CONTACTORS
£6.00
£6.00
£6.00
 
Health and Safety at Work etc Act 1974
LV and HV Cabling separation from hazardous services
FINAL CIRCUITS - LIGHTING
Health and Safety at Work etc Act 1974 LV and HV Cabling separation from hazardous services FINAL CIRCUITS - LIGHTING
£6.00
£6.00

Product rating

Customer Reviews